Search Reports


Establishment: 23905 - OGUNQUIT RIVER (POOL)
Inspection Date: 05/22/2023
Inspection Purpose: REGULAR
Status: Failed: 8 Critical, 6 Non-critical violations
Violations:
5.B.2 - Flow meter not installed and/or is not accurate.
3.A.5 - Chemical storage areas not locked at all times.
5.B.1 - Pool data sheet not posted and/or does not contain required information.
3.A.3 - Routine operating procedures not posted and/or available for viewing by the Department.
6.G.1 - Valves not tagged with metal or rigid plastic tags.
6.F - Exposed piping not color coded or color coded correctly.
3.G.4 - Material Safety Data Sheets not available for inspection.
3.A.4 - Manufacturers instructions not available.
3.G.2 - Appropriate test kit, DPD or FAS-DPD not provided, test kit not capable of testing for free and combined chlorine, pH, total alkalinity, calcium hardness and when used, cyanuric acid, reagents are over one year old and/or prohibited OTO kits and/or test strips are being used.
6.C.1 - Depth markers not present, not conspicuously marked at or above the waterline, on the vertical pool wall, and/or on top of the coping, or on the edge of the deck or on the walk next to the pool.
6.B.1 - Rope and float line not present and/or not properly placed.
6.D.3 - Ring buoy with throwing rope attached not provided, ring buoy is not US Coast Guard-approved with an outside diamenter of 15 inches or greater, throwing rope for the ring buoy not of a minimum 1/4 inch diamenter and/or throwing rope of ring buoy is not long enough (1.5 x width of pool) or 50 feet, whichever is less.
6.D.5 - First aid kit, including barrier protection (gloves and rescue breathing), not available at all times.
6.D.4 - Location of the nearest telephone not posted with dialing instructions in the immediate vicinity of the public pool or spa and/or the telephone does not have posted names and numbers of the nearest available police, fire, ambulance service and/or rescue unit.