Search Reports


Establishment: 24165 - WILDERNESS EDGE CAMPGROUND (POOL)
Inspection Date: 08/31/2023
Inspection Purpose: NEWOWNER
Status: Failed: 5 Critical, 6 Non-critical violations
Violations:
4.C.1 - Pedestrian access gate not self-closing, self-latching, opening outward, or can not accommodate a lock.
5.B.4.a.i - Circulation system does not meet turnover rate requirements for swimming pools - once every 6 hours.
5.B.3 - Disinfectant feeder not installed, not functioning properly, prohibited feeding of a supplemental sanitizer through skimmer basket is allowed, supplemental sanitizer added directly into the pool when in use, supplemental feeding of sanitizer not done in accordance with manufacturers directions, forbidden undissolved sanitizers found in skimmer basket while pool or spa in use, and/or prohibited stabilized chlorine used for indoor pools.
5.B.2 - Flow meter not installed and/or is not accurate.
5.B.1 - Pool data sheet not posted and/or does not contain required information.
6.G.1 - Valves not tagged with metal or rigid plastic tags.
6.F - Exposed piping not color coded or color coded correctly.
3.G.2 - Appropriate test kit, DPD or FAS-DPD not provided, test kit not capable of testing for free and combined chlorine, pH, total alkalinity, calcium hardness and when used, cyanuric acid, reagents are over one year old and/or prohibited OTO kits and/or test strips are being used.
3.G.1 - Sanitizer residual and pH not recorded three times a day, one manual test not conducted, proper records of maintenance and chemicals added not maintained and/or recorded once per day, total alkalinity, calcium hardness, and cyanuric acid (if used) not being tested for and recorded once per week, water chemistry records not retained for 1 year and/or the water chemistry records not available.
3.C.1 - Free chlorine levels not correct and/or stabilized chlorine used in indoor pool.
6.C.8 - The edges of steps, ledges or seats do not have a 4-inch stripe of contrasting color. Stripe should be 2 inches on the thread and 2 inches on the riser.